Language  
Skip navigation links
 Power Generation
G-Drive Diesel
Genset Diesel
Genset Gas
Genset Soundproofed
Special Generating Sets
 
G-Drive Diesel 


USA Range

N45 SM1X  -  N45SM2X  -  N45TM2X  -  N67 TM1X  -  N67 TE1X

N67 TE2X   -  C87 TE1D  -  C10 TE1D  -  C13 TE3X  -  V20 TE2

[*] = Not Emissioned

Model
Nr. Cyl/Asp.
Displ. liter
1500 rpm prime
1500 rpm Stand-by
1800 rpm Prime
1800 rpm Stand-by
8035E15.00 3L NA  2.9  29  32 
N45 AM1A 4L NA  4.5  40  44  45  50 
N45 SM1A 4L TC  4.5  53.5  59  59  65 
N45 SM2A 4L TC  4.5  66  73  65  72 
N45 TM1A 4L TAA  4.5  77  85  86  95 
N45 TM2A 4L TAA  4.5  87  96  97  107 
N67 TM2A 6L TAA  6.7  114  125  127  140 
N67 TM3A 6L TAA  6.7  138  152  150  165 
N67 TE2A 6L TAA  6.7  175  193  195  215 
C78TE2S 6L TAA  7.8  215  236  230  253 
C87 TE1D 6L TAA  8.7  232  255  251  276 
C10 TE1D 6L-TAA  10.3  260  286  282  311 
C13 TE2S 6L TAA  12.9  304  335  329  362 
C13 TE3S 6L TAA  12.9  352  387  362  398 
V20 TE1 8V TAA  20  555  610  620  680 
V20TE2 8V TAA  20  609  670  673  740 
8031i06.05 [*] 3L NA  2.9  29  32  33  36 
8041i06.55 [*] 4L NA  3.9  36  41  43  48 
N67 SM1 [*] 6L TC  6.7  110  121  126  138 
  Nr. Cyl/Asp.
L = In line vertical model
NA = Naturally aspirated
TC = Turbocharged
TAA = Turbocharged aftercooled
V = 90° V form model
  Displ. liter
Displacement liter
  1500 rpm prime
kW
The prime Power is the maximum power available with varying loads for an unlimited number of hours. The average power output during a 24 h period of operation must not exceed 80% of the declared prime power between the prescribed maintenance intervals and at standard environmental conditions. A 10% overload is permissible for 1 hour every 12 hours of operation.
  1500 rpm Stand-by
kW
This is the maximum power available for a period of 500 hours/year with a mean load factor of 90% of the declared stand-by power. No kind of overload is permissible for this use.
  1800 rpm Prime
kW
The prime Power is the maximum power available with varying loads for an unlimited number of hours. The average power output during a 24 h period of operation must not exceed 80% of the declared prime power between the prescribed maintenance intervals and at standard environmental conditions. A 10% overload is permissible for 1 hour every 12 hours of operation.
  1800 rpm Stand-by
kW
This is the maximum power available for a period of 500 hours/year with a mean load factor of 90% of the declared stand-by power. No kind of overload is permissible for this use.